LOW VOLTAGE ARRESTERS

Transformers Components manufactures a distributing lightning arrester for the low voltage side of single and three phase distribution transformers. The arrester may be used with pole and padmount distribution transformer applications.

Single Phase

Three Phase

Single Phase Low Voltage Arrester

ECI manufactures a distribution lightning arrester for the low voltage side of single and three phase distribution transformers. The arrester may be used with pole and pad mounted distribution transformer applications.

 

Arrester voltage options are:

Single Phase

o   120/240 volt

o   277 volt

 

The arrester has been designed and tested in accordance with ANSI/IEEE Standard C62.11 Light Duty Distribution Class requirements. Being a true distribution class lightning arrester, the transformer is offered optimal protection against low side surges.

Studies have shown that surges can enter the low voltage side of a transformer from lightning strikes that hit the secondary service wires or from strikes hitting the primary wires if the transformer ground is above 25 ohms. A low voltage distribution class arrester can protect the transformer coil from these normally damaging lightning surges.


Product NumberArrester Rating (V rms)Description
Single Phase  
9F95DA480480No Terminal
9F96DA250250No Terminal
9F96DA480480No Terminal
9F96DB4804803/8″ Terminal
9F96DC4804801/2″ Terminal

Three Phase Low Voltage Arrester

 

ECI manufactures a distribution lightning arrester for the low voltage side of single and three phase distribution transformers. The arrester may be used with pole and pad mounted distribution transformer applications.

 

Arrester voltage options are:

Three Phase

o   208Y/120 volt

o   480Y/277 volt

 

The arrester has been designed and tested in accordance with ANSI/IEEE Standard C62.11 Light Duty Distribution Class requirements. Being a true distribution class lightning arrester, the transformer is offered optimal protection against low side surges.

Studies have shown that surges can enter the low voltage side of a transformer from lightning strikes that hit the secondary service wires or from strikes hitting the primary wires if the transformer ground is above 25 ohms. A low voltage distribution class arrester can protect the transformer coil from these normally damaging lightning surges.

 

 

 Product NumberArrester Rating (V rms)Description
Three Phase  
9F97DA250250No Terminal
9F97DA480480No Terminal
9F97DB4804803/8″ Terminal
9F97DC4804801/2″ Terminal